<address id="ndxf9"></address>

            <sub id="ndxf9"></sub>
            產品展示
            PRODUCT DISPLAY
            產品展示您現在的位置: 首頁 > 產品展示 > 臺灣儀鼎PICOTEST > PICOTEST測試訊號轉換器 > J2101A臺灣儀鼎PICOTEST專業測試訊號轉換器

            臺灣儀鼎PICOTEST專業測試訊號轉換器

            更新時間:2020-03-31
            瀏覽次數:639
            簡要描述:

            臺灣儀鼎PICOTEST專業測試訊號轉換器J2101A Low band corner frequency 達10Hz,可支援一般離線式電源供應器(off-line power supplies)之測量,45MHz之超高頻寬,足以對應目前及未來Z先進之穩壓器量測需求,超高頻寬,可達23 Octave,優異精確的低失真表現,5Ω終端,對待測電路的影響降至Z小,包括衰減功能來確保小信號的測量正確性

            在線咨詢

            臺灣儀鼎PICOTEST專業測試訊號轉換器

            J2101A Injection Transformer 10Hz~45MHz 

             
             
             
            iconLow band corner frequency 達10Hz,可支援一般離線式電源供應器(off-line power supplies)之測量
            icon45MHz之超高頻寬,足以對應目前及未來zui先進之穩壓器量測需求
            icon超高頻寬,可達23 Octave
            icon優異精確的低失真表現
            icon5Ω終端,對待測電路的影響降至zui小
            icon包括衰減功能來確保小信號的測量正確性
            icon詳細規格
            臺灣儀鼎PICOTEST專業測試訊號轉換器
            Product Information

            The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.

            The usable bandwidth of an injection transformer is generally significantly greater than the 3dB frequency limits. This is because the transformer itself is outside of the measurement, leading many to incorrectly believe that the transformer is a non-critical element.

            The bandwidth of the transformer is strongly related to the terminating impedance. The most network analyzers provide a 50 Ohm oscillator source impedance. Assuming this impedance the optimal termination resistor is 5 Ohms. This significantly attenuates the injection signal, which is generally beneficial, as a common error in Bode measurements is using a signal which is too large, and therefore not a small signal measurement. An added benefit of this low value is that it can generally be left in circuit at all times, simplifying the connection to the network analyzer without appreciably impacting the output voltage of the circuit being tested.

            Detailed Specifications:
             
            Performance at -10dBm input level
            CharacteristicRating
            DCR 
            Ratio1:1
            Termination Impedance5 Ohms
            Nominal 3dB Bandwidth10Hz ~ 45MHz
            Isolation Voltage600V
            Isolation Capacitance150pF@1KHz
            DC Current10mA
            Temperature Range0 ~ 50°C
            Maximum Altitude6000 Ft
            聯系方式
            • 服務熱線:

              4009023318

              13913158248

              15295666126

            • 公司電話:

              0512-66315386

            • 公司傳真:

              0512-66315383

            在線客服
            • 技術支持:
            • 產品咨詢:

            乐喜彩票
            掃一掃訪問手機站掃一掃訪問手機站
            訪問手機站